Withdrawal
1. If the door has a power window and central locking (see note at the beginning of this chapter), disconnect the cable from the negative battery terminal.
2. Raising the glass all the way up, remove the inner door panel (see section 11).
3. Secure the glass in the up position with adhesive tape by sticking it to the glass and wrapping it around the door frame (put a rag over the door so that the tape does not come into contact with the seal). Do not proceed further until you are sure that the tape is supporting the weight of the glass.
4. Punch out the center pins of the rivets holding the window regulator and drill out the rivets with a 3/16" drill bit (manual drill) or 1/4 inch diameter (electric drill) (see illustration).
20.4. Drill Rivets Power Window Mounting Door Window (indicated by arrows)
5. If an electric window lifter is installed on the door, disconnect its electrical connector.
6. Move the power window until it disengages from the rail. Raise the power window and remove it from the door.
7. To disconnect the electric motor of a window regulator from the mechanism, drill out rivets of fastening of the mechanism and the lift electric motor.
Installation
8. Insert the power window mechanism into place in the door and engage it with the frame.
9. Attach the power window to the door using a hand riveter and 3/16" or 1/4" rivets, or use 1/2" bolts to attach the adjuster.
10. Connect the wiring connector (if there).
11. Install the inner door panel. Connect the wire to the negative terminal of the battery.