Withdrawal
1. Pump out the coolant from the air conditioning system.
2. Turn away a bolt of fastening of a hose of a supply of refrigerant to the conditioner compressor. Tightening torque 16 Nm.
3. Disconnect the refrigerant supply hose (2) from the compressor.
4. Turn away a nut of fastening of a hose of a supply of refrigerant to the conditioner accumulator. Tightening torque 16 Nm.
5. Disconnect the hose from the battery.
6. Remove the coolant supply hose from the vehicle.
7. Remove and discard all sealing washers. Place plugs on the open ends of the tubes.
Installation
8. Installation is carried out in the reverse order.
9. Evacuate the system and charge the system with refrigerant.
10. Check the system for refrigerant leaks.