Withdrawal
Delphi
1. (Models up to 2005) Remove the upper and lower trims of the instrument panel.
2. (Models up to 2005) Remove the front passenger airbag.
3. (Models up to 2007) Remove the central air duct.
4. (Models since 2007) Open the glove box. Detach the glove box retainers from the instrument panel and fully open the glove box.
1 - screw, 2 - recirculation mode servo
5. Disconnect the recirculation mode servo harness connector (1).
6. Turn away screws of fastening of the servomotor of a recirculation mode. Tightening torque 2 Nm.
7. Remove the servo.
8. Installation is carried out in the reverse order.
Visteon
1. Remove the air conditioning unit.
2. Loosen the evaporator radiator cap screws (1). Tightening torque 2 Nm.
3. Remove the evaporator radiator cap (1) from the air conditioning unit (2).
4. Loosen the screws securing the recirculation mode servo (1). Tightening torque 2 Nm.
5. Remove the recirculation mode servo (1) from the air conditioning unit (2).
Installation
6. Installation is carried out in the reverse order.
7. Calibrate the climate control servomotors.