Withdrawal
1. Remove the evaporator radiator.
2. Carefully remove the seal.
3. Remove the retainer securing the evaporator tube to the expansion valve.
4. Disconnect the evaporator tube from the expansion valve. Tightening torque 28 Nm.
5. Remove expansion valve.
Installation
6. Installation is carried out in the reverse order.