Starter Specifications
Description
|
Unit
|
Standard
|
Type
|
-
|
PG 260D
|
Capacity; Volume; Performance; Power; Working volume
|
kW
|
1,4
|
Drive gear revolutions (Test without load at 12 V)
|
rpm
|
2600 min.
|
Brush length
|
mm (in.)
|
8.25
|
Anchor diameter
|
mm (in.)
|
45.5
|
Anchor beat
|
mm (in.)
|
0.08
|
Depth at segment start position
|
mm (in.)
|
0,6~1,0
|
Generator Specifications
Description
|
Unit
|
Standard
|
||||
Type
|
-
|
AD237
|
||||
Capacity; Volume; Performance; Power; Working volume
|
a/h
|
120
|
||||
Regulator type
|
-
|
Generic/Non RVC
|
||||
Voltage regulator
|
IN
|
14.6± 0.25 at Tb=25°С, 6000 rpm, 50% load
|
||||
Brush
|
Length
|
mm (in.)
|
18,8
|
|||
Qty
|
EA
|
2
|
||||
Min. length
|
mm (in.)
|
8.0
|
Battery Specifications
Description
|
Unit
|
Standard
|
Type
|
-
|
MF
|
Capacity; Volume; Performance; Power; Working volume
|
a/h
|
70
|
And, cranking the crankshaft is not programmable. engine (CCA)
|
CCA
|
770
|
Min. standby power (RC)
|
min.
|
110
|
Load test
|
A
|
380
|
Minimum voltage:
|
||
|
IN
IN
IN
IN
IN
IN
IN
IN
|
70°F (21°C) and higher
60°F (15.6°С)
50°F (10°С)
40°F (4.4°С)
30°F (-1.1°С)
20°F (-6.7°С)
10°F (-12.2°С)
0°F (-17.8°С)
|
Specifications for spark plugs
Description
|
Unit
|
Standard
|
Type
|
-
|
HR7MPP302 (BOSCH)
|
Gap
|
mm (in.)
|
1.1 (0.0433)
|
Tightening torques for threaded connections
PROGRAM
|
N·m
|
lb-ft
|
lb-in
|
Auxiliary drive belt guide pulley through bolt to alternator
|
58
|
43
|
-
|
Upper alternator mounting bolts
|
50
|
37
|
-
|
Nut of fastening of the bringing wire of the generator to the accumulator battery
|
15
|
11
|
-
|
Starter mounting bolts assy
|
45
|
33
|
-
|
Nut for fastening the lead wire from the battery to the starter solenoid valve
|
15
|
11
|
-
|
Nut for fastening the lead wire of the main engine wiring harness to the starter solenoid valve
|
10
|
-
|
89
|
Battery tray locking screws
|
10
|
-
|
89
|
Engine Fuse Box Bottom Cover Screws
|
10
|
-
|
89
|
Engine Fuse Block Locking Screws
|
3
|
-
|
27
|
Battery Clamp Locking Screws
|
10
|
-
|
89
|