Withdrawal procedure
1. Remove the V-ribbed drive belt for auxiliary systems. This operation is described in section «Maintenance».
2. Disconnect the hydraulic pump pressure (1) and serving (2) tubes. Drain the oil from the hydraulic system into a prepared container.
3. Loosen the nuts (3) mountings of the hydraulic pump and remove it. When installing, tighten the nuts to a torque of 25 Nm.
4. Installation is carried out in the reverse order.
5. After installation, fill the system with oil and bleed the air from the hydraulic system.